The Primozone Enclosure Dryer Module (EDM) is a smart, efficient solution designed to prevent condensation and moisture build‑up inside the cabinet of any Primozone GM‑Series ozone generator. Moisture is one of the most common causes of electrical faults, corrosion, and reduced performance in ozone systems. The EDM ensures a dry, stable internal environment, protecting sensitive components and extending the lifespan of your equipment.
Compatible with all GM‑Series models, the EDM is essential for installations operating in humid environments, warm climates, or facilities with fluctuating temperatures.
The EDM is engineered to remove moisture from the air entering the ozone generator enclosure, significantly reducing the risk of condensation forming inside the cabinet. By maintaining a dry internal atmosphere, the EDM helps ensure:
Reliable long‑term operation
Reduced risk of electrical failure
Improved ozone generator performance
Extended equipment lifespan
It is a simple, effective way to protect your investment.
All the EDM requires is a source of compressed air. The system:
Takes a small flow of compressed air
Passes it through a membrane dryer
Injects a controlled amount of dry air into the ozone generator enclosure
Continuously flushes out moisture‑laden air
This constant circulation of dry air prevents humidity from entering the cabinet, ensuring a stable, moisture‑free environment for the generator’s electronics and reactor components.
Prevents condensation inside the generator cabinet
Protects sensitive electronics from moisture damage
Improves long‑term reliability
Compatible with all GM‑Series models
Simple installation
Ideal for humid or temperature‑variable environments
Retrofit kit available
Moisture can cause corrosion, electrical faults, and reduced performance. The EDM prevents condensation and protects internal components.
Yes. The EDM is compatible with all GM‑Series ozone generators.
Only a compressed air supply is required.
Yes. A retrofit kit (Article No. 110182) is available for older GM units.
It injects a small flow of dry air into the enclosure, continuously flushing out moisture‑laden air.
Maintenance is minimal. The membrane dryer and airflow system are designed for long‑term, reliable operation.
Absolutely. It is specifically designed for installations exposed to humidity, temperature swings, or damp conditions.
Whenever an ozone generator operates in a humid, damp, or temperature‑variable environment.
Yes. Moisture can corrode electronics, cause short circuits, and reduce ozone output.
Yes. It is compatible with all GM‑Series ozone generators.
Not always, but it is recommended if humidity or temperature conditions fluctuate.
Yes. A retrofit kit is available for existing installations.
No. It uses only a small, controlled flow to keep the enclosure dry.
Already have a Primozone GM‑Series generator installed? A dedicated retrofit kit (Article No. 110182) is available, making it easy to upgrade older units with EDM protection.
Installation guidance is provided in the Operation & Installation Manual, ensuring a smooth and straightforward upgrade.
The Primozone Enclosure Dryer Module (EDM) is essential anywhere an ozone generator operates in humid, temperature-variable, or moisture-prone environments. Moisture is one of the leading causes of electrical faults, corrosion, and reduced performance in ozone systems. The EDM prevents condensation inside the generator cabinet, ensuring long-term reliability.
BelowarethekeyapplicationswhereanEDMisnotjustuseful—it’snecessary.
Facilities with naturally high moisture levels require constant cabinet drying to prevent condensation, including:
Tropical or warm‑climate installations
Indoor facilities with poor ventilation
Water treatment plants with high ambient humidity
Ozone generators installed near:
Open tanks
Aeration basins
Clarifiers
Wet wells
are exposed to moisture‑rich air, making EDM protection essential.
Aquaculture environments are humid by nature due to:
Warm water
Splash zones
High evaporation
Enclosed fish rooms
The EDM prevents moisture from entering the ozone generator enclosure.
Industries using ozone for:
Cooling water
CIP rinse water
High‑purity water
Chemical oxidation
often operate in damp or steam‑rich environments where condensation risk is high.
Food factories frequently experience:
Steam
Wash‑downs
Temperature swings
High humidity
The EDM ensures stable ozone generator performance in these conditions.
Purified water and WFI rooms often have:
Controlled but humid environments
Temperature fluctuations
Condensation risks
The EDM protects sensitive ozone equipment from moisture damage.
Cold rooms and chilled warehouses experience:
Temperature cycling
Condensation when doors open
Moisture‑laden air
The EDM prevents condensation inside the ozone generator cabinet.
Ozone systems installed near:
Wet scrubbers
Biofilters
Packed towers
are exposed to moisture and require EDM protection.
Frequent system changes and variable conditions increase condensation risk. The EDM ensures stable internal conditions regardless of external fluctuations.
Please send us your enquiries via the following email form.